|
Microelectrodes Inc
3d pyrolytic carbon ![]() 3d Pyrolytic Carbon, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/suspended+3d+pyrolytic+carbon/pmc09550156-1-0-3 Average 90 stars, based on 1 article reviews
3d pyrolytic carbon - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Microelectrodes Inc
3d micro-electrodes ![]() 3d Micro Electrodes, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+micro+electrodes/us11668698-33-7-8 Average 90 stars, based on 1 article reviews
3d micro-electrodes - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Axion BioSystems
the 3d microelectrode array 20 ![]() The 3d Microelectrode Array 20, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/the+3d+microelectrode+array+20/us12195718-72-11-23 Average 90 stars, based on 1 article reviews
the 3d microelectrode array 20 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Microelectrodes Inc
with 3d interdigital structures ![]() With 3d Interdigital Structures, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/with+3d+interdigital+structures/pmc09552904-60-2-0 Average 90 stars, based on 1 article reviews
with 3d interdigital structures - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Microelectrodes Inc
3d carbon microelectrodes ![]() 3d Carbon Microelectrodes, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+carbon+microelectrodes/10__1016_slash_j__carbon__2017__05__090-180-7-9 Average 90 stars, based on 1 article reviews
3d carbon microelectrodes - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Microelectrodes Inc
3d sma microelectrodes with cliipping structure ![]() 3d Sma Microelectrodes With Cliipping Structure, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+sma+microelectrodes+with+cliipping+structure/10__5772_slash_25867-88-5-3 Average 90 stars, based on 1 article reviews
3d sma microelectrodes with cliipping structure - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Dassault Systemes
3d microelectrode array 20 ![]() 3d Microelectrode Array 20, supplied by Dassault Systemes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+microelectrode+array+20/us11746320-163-2-17 Average 90 stars, based on 1 article reviews
3d microelectrode array 20 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Omnetics Connector Corporation
3d microelectrodes ![]() 3d Microelectrodes, supplied by Omnetics Connector Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+microelectrodes/pmc09772315-153-18-27 Average 90 stars, based on 1 article reviews
3d microelectrodes - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Microelectrodes Inc
3d microelectrodes embedded in microchannels of microfluidic devices ![]() 3d Microelectrodes Embedded In Microchannels Of Microfluidic Devices, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+microelectrodes+embedded+in+microchannels+of+microfluidic+devices/us11661469-328-32-29 Average 90 stars, based on 1 article reviews
3d microelectrodes embedded in microchannels of microfluidic devices - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Microelectrodes Inc
3d-nanostructured array microelectrodes ![]() 3d Nanostructured Array Microelectrodes, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+nanostructured+array+microelectrodes/10__1016_slash_j__coelec__2021__100924-57-23-24 Average 90 stars, based on 1 article reviews
3d-nanostructured array microelectrodes - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Ayanda GmbH
3d recording microelectrodes ![]() 3d Recording Microelectrodes, supplied by Ayanda GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+recording+microelectrodes/pmc02652101-36-9-50 Average 90 stars, based on 1 article reviews
3d recording microelectrodes - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
DuPont de Nemours
3d microelectrode arrays (meas) ![]() 3d Microelectrode Arrays (Meas), supplied by DuPont de Nemours, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/3d+microelectrodes/3d+microelectrode+arrays++meas+/pmc08229631-40-0-17 Average 90 stars, based on 1 article reviews
3d microelectrode arrays (meas) - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Mikrochimica Acta
Article Title: New carbon black-based conductive filaments for the additive manufacture of improved electrochemical sensors by fused deposition modeling
doi: 10.1007/s00604-022-05511-2
Figure Lengend Snippet: Comparison of the analytical characteristics obtained with PB/CB-PLA for the detection of hydrogen peroxide with works reported in the literature
Article Snippet:
Techniques: Comparison
Journal: Nanoscale Advances
Article Title: Miniaturized lithium-ion batteries for on-chip energy storage
doi: 10.1039/d2na00566b
Figure Lengend Snippet: Schematic diagrams of various micro-LIBs according to different cell microstructures: (a) laminated thin film structure, (b) planar interdigital structure, (c) 3D interdigital structure, (d) other types of 3D architecture (microtube structure).
Article Snippet:
Techniques:
Journal: Microsystems & Nanoengineering
Article Title: A flexible protruding microelectrode array for neural interfacing in bioelectronic medicine
doi: 10.1038/s41378-022-00466-z
Figure Lengend Snippet: a Sketch of the neural interface with protruding microelectrodes decreasing the distance to the neurons. b Layout of neural interface design with dimensions and compartment descriptions. c Process flow for the microfabrication of a flexible polyimide-based 3D MEA. d Schematic view of the MFI technique connecting a flexible MEA with a rigid printed circuit board (PCB). A tiny gold ball (~Ø 90 µm) is formed at the capillary by the flame-off electrode. The gold ball is pushed against the hole of the MEA contact pad onto the heated PCB bond pad with a defined force and ultrasonic energy connecting the components mechanically and electrically. Finally, the capillary is lifted, and the gold wire is cut off, leaving a tiny gold stud that acts as a microrivet between the MEA and the PCB
Article Snippet: Fig. 4 Fabricated 3D neural interface. a Photograph of the fabricated neural device showing the flexible MEA with
Techniques:
Journal: Microsystems & Nanoengineering
Article Title: A flexible protruding microelectrode array for neural interfacing in bioelectronic medicine
doi: 10.1038/s41378-022-00466-z
Figure Lengend Snippet: a Photograph of the fabricated neural device showing the flexible MEA with 3D microelectrodes connected to a PCB with a soldered Omnetics connector. b Assembling of the neural interface. b-i Macroscopic image of the MEA connector with the corresponding PCB. b-ii Scanning electron microscopy (SEM) image of an assembled neural device with finger structures electrically connected by microrivets to the underlying PCB. b-iii SEM image of a single gold bump stud connecting the neural interface contact pad to the PCB bond pad. The entire hole is filled and covered by the gold stud, which acts as a microrivet. c Macroscopic images of the neural interface with compartment descriptions and functions of the entire measurement field ( c-i ) and of the area with electrodes arranged in a chessboard pattern ( c-ii ). The electrode heads were coated with TiN, which appears black in the images. d Macroscopic images ( d-i , d-ii ) and SEM images ( d-iii , d-iv ) of an MEA and of a single microelectrode (Ø 50 µm, height ~50 µm). The pillars exhibit parylene C side insulation, and their heads were wet etched and coated with TiN. The microelectrode shown in d-iv has a TiN coating on its head of 4–5 µm height. e SEM images of single modified microelectrodes, which were either wet etched ( e-i , e-ii ) or wet etched and TiN-coated ( e-iii , e-iv ) (both Ø 20 µm with a height of ~60 µm). The pillars were etched by RIE (Fig. , step i) until the parylene C was removed from the exposed tops and sides of the pillar heads. Scale bars: b - i : 2 mm, c - ii : 1 mm; b - ii : 500 µm; d - iii : 200 µm; b - iii , d - iv , e - i , e - iii : 20 µm; e - ii , e - iv : 1 µm
Article Snippet: Fig. 4 Fabricated 3D neural interface. a Photograph of the fabricated neural device showing the flexible MEA with
Techniques: Electron Microscopy, Modification
Journal: PLoS ONE
Article Title: Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study
doi: 10.1371/journal.pone.0004828
Figure Lengend Snippet: A: Top view of the experimental MEA chamber (A1). The “spinal MEA” from Ayanda BioSystems consists of 4×15 3D recording electrodes (arrows in A2) and 8 2D stimulation electrodes (rectangles in A2). Current-controlled monopolar stimulations were applied between a 2D stimulation electrode and an external cylindrical Ag/AgCl ground electrode. The potential field V generated in the medium was measured by the 60 recording microelectrodes, and the stimulation electrode voltage ( V metal = V stim ) was recorded with a home-made follower circuit. Peak values were measured at the end of the cathodic phase of the pulse stimulus (see example in A3). B: Top view of the 3D finite element model used for the computation of the potential field. The 60 recording electrodes were modeled by cones, and the stimulation electrode by a 2D rectangular surface on the substrate (B2). All these electrodes were represented as surface boundaries in the finite element model. When present, the neural tissue was modeled as a 200-µm-thick parallelepiped with a different electrical conductivity than that of the Ringer solution (B3). The 3D mesh consisted of 63,214 tetrahedral Lagrange P2 elements, corresponding to 101,105 degrees of freedom (B4).
Article Snippet: The array was composed of a 4×15 grid of
Techniques: Generated
Journal: Sensors (Basel, Switzerland)
Article Title: Inkjet-Printed and Electroplated 3D Electrodes for Recording Extracellular Signals in Cell Culture
doi: 10.3390/s21123981
Figure Lengend Snippet: 3D illustrations of the two methods for printing 3D microelectrode arrays: ( a , b ) stationary and ( c , d ) continuous.
Article Snippet:
Techniques:
Journal: Sensors (Basel, Switzerland)
Article Title: Inkjet-Printed and Electroplated 3D Electrodes for Recording Extracellular Signals in Cell Culture
doi: 10.3390/s21123981
Figure Lengend Snippet: Tilt-corrected scanning electron microscope images of ( a ) a sintered 3D microelectrode array, ( b ) a pillar under focused ion beam analysis, and ( c ) a pillar after bulk milling and polishing. Different magnifications of the pillar shown in ( c ) are shown in ( d – f ). All pillars were printed with approx. 1600 droplets of AgNP ink, displaying a width of ~32 μm and a height of 500–560 μm. All images were captured using an acceleration voltage of 3 kV and a substrate tilted at 52–54°. Scale bars represent ( a ) 500 μm, ( b ) and ( c ) 100 μm, ( d ) 10 μm, ( e ) 1 μm, and ( f ) 100 nm.
Article Snippet:
Techniques: Microscopy, Microelectrode Array
Journal: Sensors (Basel, Switzerland)
Article Title: Inkjet-Printed and Electroplated 3D Electrodes for Recording Extracellular Signals in Cell Culture
doi: 10.3390/s21123981
Figure Lengend Snippet: ( a ) Magnitude and ( b ) phase of the impedance of electroplated Ag-Au-Pt 3D microelectrodes, which were printed with different droplet numbers. The mean and standard deviation (solid line and shaded area, respectively) were calculated using 4 samples. ( c – l ) Tilt-corrected SEM images of the same 3D microelectrodes taken at a substrate tilt of ( c – g ) 0° and ( h – l ) 45°. All SEM images used an acceleration voltage of 15 kV. A magnification of ( c – j ) 1000×, ( k ) 350×, and ( l ) 250× was used. All scale bars shown have a length of 40 μm. The numbers in the legend and the upper right corner of the SEM images correspond to the amount of ejected Ag nanoparticle droplets.
Article Snippet:
Techniques: Standard Deviation